"ERROR" in the Display
"ERROR" indicator in the display
Cause: Addition/subtraction of measured values with different units of measurement
Corrective measure: Add/subtract only measured values with the same units of measurement
Cause: Angle between laser beam and target is too sharp
Corrective measure: Increase the angle between the laser beam and target
Cause: Target surface is reflecting too strongly (e.g. mirror) or too weakly (e.g. black material), or ambient light is too strong
Corrective measure: Use a laser target plate (accessory)
Cause: Laser beam output (21) or reception lens (20) is fogged up (e.g. due to rapid temperature change)
Corrective measure: Rub the laser beam output (21) or the reception lens (20) dry with a soft cloth
Cause: Calculated value is larger than 1 999 999 or smaller than -999 999 m/m²/m³
Corrective measure: Split the calculation into intermediate steps