Technical Data

Line laser

GLL 50-15 XG

Article number

‎3 601 K65 7..‎‎‎‎

Working rangeA)

  • Standard laser lines

15 m

  • Laser lines with receiver mode

10 m

  • Laser lines with laser receiver

5–50 m

  • Plumb point

5 m

Levelling accuracyB)C)D)

  • Horizontal laser line

±0.2 mm/m

  • Vertical laser lines

±0.3 mm/m

  • Plumb point

±0.7 mm/m

Self-levelling range

±2.5°

Levelling time

< 4 s

Operating temperature

–10 °C to +45 °C

Storage temperature

–20 °C to +70 °C

Max. altitude

2000 m

Relative air humidity max.

90%

Pollution degree according to IEC 61010-1

2E)

Laser class

2

Laser line

  • Laser type

< 10 mW, 500–540 nm

  • Colour of the laser beam

Green

  • C₆

10

  • Divergence

50 × 10 mrad (full angle)

Plumb point

  • Laser type

< 1 mW, 630–650 nm

  • Colour of the laser beam

Red

  • C₆

1

  • Divergence

0.8 mrad (full angle)

Pulse frequency

  • Operating without receiver mode

23 kHz

  • Operating with receiver mode

10 kHz

Tripod mountF)

5/8"

Batteries

4 × 1.5 V LR6 (AA)

Weight (with batteries)

0.54 kg

Dimensions (length × width × height)

  • Without rotating platform

122 × 83 × 129 mm

  • With rotating platform

Dia. 151 × 203 mm

Protection rating (excluding battery compartment)

IP54

A)

The working range may be reduced by unfavourable environmental conditions (e.g. direct sunlight).

B)

At 20–25 °C

C)

The values stated presuppose normal to favourable environmental conditions (e.g. no vibration, no fog, no smoke, no direct sunlight). Extreme fluctuations in temperature can cause deviations in accuracy.

D)

An additional deviation of ±0.1 mm/m must be taken into account when at maximum self-levelling range.

E)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

F)

Only available in combination with the rotating platform

The serial number (4) on the type plate is used to clearly identify your measuring tool.